> For the complete documentation index, see [llms.txt](https://docs.wcproducts.com/welcome/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.wcproducts.com/welcome/electronics/kraken-x60/kraken-x60-motor/how-to-articles/connecting-cooling-ports.md).

# Connecting Cooling Ports

To help with cooling, the Kraken X60 has (2x) #10-32 tapped holes on the side. This allows teams to install up to (2x) pneumatic fittings to assist with cooling motors between matches or while practicing at home for extended periods of time.&#x20;

Having two cooling ports gives teams the option of plumbing motors together, allowing for a single inlet to push air through multiple motors at once.

{% hint style="danger" %}
The cooling ports provide a pathway into the motor and should be protected when not in use. An unprotected cooling port can allow debris to enter the motor and can cause **permanent damage** to the motor.
{% endhint %}

{% hint style="danger" %}
**Is cooling required?**

No. This is an optional feature that was added for teams practicing at home. Forcing cool air into the motors can reduce the downtime between practice matches. All thermal testing was done without actively cooling the motors.
{% endhint %}

## Step 1

Remove the (2x) #10-32 bolts located on the side of the Kraken X60 Motor

{% hint style="info" %}
If only one pneumatic fitting is being installed, it is recommended to remove the second #10-32 bolt to allow air to flow out of the motor.
{% endhint %}

<figure><img src="/files/AwVIw5JbfzwjdFy88MaG" alt="" width="563"><figcaption></figcaption></figure>

## Step 2

Install the pneumatic fittings.

{% hint style="info" %}
Recommended air fitting ([McMaster 5779K286](https://www.mcmaster.com/5779K286/)).
{% endhint %}

<figure><img src="/files/rOX4DiZEc4fCpYjYfSws" alt="" width="563"><figcaption></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://docs.wcproducts.com/welcome/electronics/kraken-x60/kraken-x60-motor/how-to-articles/connecting-cooling-ports.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.